Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Horizontal Rotary Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GW9
Number of Poles
Three Pole
Structure of Operating
Electric
Rated Frequency
50Hz
Rated Voltage
12kv
Rated Current
400/630A
Mechanical Life
2000times
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
853530900
Production Capacity
10000PCS/Yea

Product Description

Photos of product
Gw9-24 Series 3-Phase Outdoor High-Voltage AC Single Pole Isolation SwitchGw9-24 Series 3-Phase Outdoor High-Voltage AC Single Pole Isolation Switch
GENERAL

GW9-24 series outdoor high-voltage AC single pole isolation switches (hereinafter referred to as "isolation switch") are outdoor high-voltage power distribution equipment with a rated voltage of 24kV and three-phase AC 50Hz, which are applicable to 20kV high-voltage transmission lines to cut off and close single-phase or three-phase circuits without load and voltage.

The rated current of the isolation switch is 200A, 400A, 600A, and 1000A.

The isolation switch is composed of a low-voltage, porcelain post insulator, a conductive part, and a mechanical part. The knife switch structure is adopted for opening and closing to cut off and close the electrical circuit. Each phase of the knife switch is composed of two conductive blades. Compression springs are installed on both sides of the blade. The contact pressure required for the knife switch can be obtained by adjusting the height of the spring. When the isolation switch is opened and closed, the insulating hook bar operating mechanism can be opened and closed. The disconnector has no self-locking device.

Isolation switches are generally suitable for transformers on three-phase line systems. The utility model has the advantages of simple structure, beautiful appearance, simple operation, and maintenance.
The isolation switch shall comply with the technical standards such as High Voltage AC Disconnectors and Earthing Switches (GB/T 1985-2004) and Technical Conditions for Ordering AC High Voltage isolation switches and Earthing Switches (DL/T 486-2000).



MODEL AND MEANING
Gw9-24 Series 3-Phase Outdoor High-Voltage AC Single Pole Isolation Switch
USAGE: ENVIRONMENTAL CONDITIONS
1. The altitude does not exceed 3000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa. (corresponding to 34m/s wind speed).
4. Atmospheric relative humidity: Dailly average does not exceed 95%, Monthly average does not exceed 90%
5. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction areas; however, it shouldn't be any explosive matters and matters causing a fire.


Gw9-24 Series 3-Phase Outdoor High-Voltage AC Single Pole Isolation Switch
TECHNICAL PARAMETERS
 
NO. ITEM UNIT DATA
1 Rated frequency Hz 50
2 Rated voltage kV 12
3 Rated current A 400 , 630
4 Rated Short-time Withstand Current  kA 16 , 20
5 Rated Peak Withstand Current kA 40 , 50
8 Rated Short-time Withstand Current Continuous Time s 4
9 1 min Power Frequency Withstand Voltage kV 65/79 (Fracture)
10 Rated Lightning Impulse Withstand Voltage kV 125/145 (Fracture)
11 Mechanical Life Times 2000
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.


OUTSIDE APPEARANCE AND INSTALLATION DIMENSION
Gw9-24 Series 3-Phase Outdoor High-Voltage AC Single Pole Isolation Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15