• 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
  • 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
  • 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
  • 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
  • 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
  • 10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price

10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price

Application: Metering
Type: Current Transformer
Phase: Single
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price pictures & photos
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
US $40-90 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Zhejiang, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)

Basic Info.

Model NO.
LZZB11-10
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rated Secondary Current
5A or 1A
Insulation Level
12/42/75kv
Rated Frequency
50Hz or 60Hz
Weight
11kg
Power Factor
Cosφ=0.8
Air Relative Site
Air Relative Site
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
22.00cm * 15.00cm * 22.00cm
Package Gross Weight
11.000kg
Lead Time
10 days (1 - 50 Pieces)
To be negotiated ( > 50 Pieces)

Product Description

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price


General

This type of voltage transformer adopts epoxy-resin vacuum casting and a fully closed single-phase structure for indoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and voltage measurement.
It complies with the standards GB 20840.1-2010 Instrument transformers-Part1:General requirements, GB 20840.3-2013 Instrument transformers-Part3:Additional requirements for inductive voltage transformers, and JJG314-2010 Instrument Voltage Transformers.


Use environment
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative humidity:≤85%
  4. Air relative site: indoor.
Technical parameter
  1. Insulation level:12/42/75kV
  2. Power factor:cosφ=0.8
  3. Rated frequency:50Hz or 60Hz
  4. Weight: 11kg
Technical ratio
 

Rated primary current
(A)

Accuracy class

Rated output
(VA)

Rated short-time
thermal current (kA/S)

Rated Insulation
level  (kA)
5 0.2S 10 0.36 0.9
10 0.72 1.8
15 1.08 2.7
20 1.44 3.6
25 1.8 4.5
30 2.16 5.4
40 2.88 6.3
50 3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 90
 
Outline and Dimensions

10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price

Our Customer

Our customers are located all over the world.
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
Test Reports

All products have undergone professional testing and certification
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers PricePhotos of Product
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
Eng. ADOFO MICHAEL ADJEI / BSc, MSc
Project Manager, Foreign Trade and Technology
Denggao Electric Co. Ltd
Head Office: No 208 Weiwu Lu, Economic Development Zone. Yueqing - China
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price pictures & photos
10 Kv CT Fully Single Phase Sealed Types of Energy Meter Current Transformer Instrument Transformers Price
US $40-90 / Piece
Min. Order: 1 Piece

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
385
Year of Establishment
1996-09-15