• Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear
  • Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear
  • Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear
  • Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear
  • Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear
  • Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear

Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear

Certification: CCC, ISO9001
Shell Material: Aluminum Alloy
Voltage Level: Medium Voltage
Installation: Fixed
Structure: Withdrawable
Standard: IEC62271-200, IEC62271-100
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
XGN66
Rated Voltage
12kv
Rated Frequency
50Hz
Mechanical Life
20000times
Trademark
DGG
Origin
China
HS Code
853720900
Production Capacity
100sets/Year

Product Description

Photos of Product

General

Xgn66-12 box type fixed AC metal-enclosed switchgear (hereinafter referred to as simple switchgear) is a new generation of a complete set of high-voltage electrical appliances designed and developed by our factory, which meets the requirements of the national standard GB3906 "3 ~ 35kV AC metal-enclosed switchgear" and the Ministry of electric power DL / t404 "technical conditions for ordering indoor AC high-voltage switchgear", It also meets the requirements of the international standard iec60298 AC metal-enclosed switchgear and control equipment above 1kV and below 25kV.

This product has absorbed the advanced technology of foreign countries and is designed and developed for the problems of high accident rates and a large volume of existing similar switchgear in China. It has the advantages of small cabinet volume (only 50% of the volume of an ordinary switch cabinet), good circuit breaker performance, high reliability, and a reliable and simple "five prevention" interlocking mechanism.

Model And Meaning

Xgn66-12 Box Type Fixed AC Metal Enclosed Switchgear


Normal Service Conditions

a. Ambient temperature: no more than + 40 ºC; At least - 15 ºC;
b. Environmental humidity: relative humidity: the daily average value shall not exceed 95%, and the monthly average value shall not exceed 90%; Water vapor pressure: the daily average value shall not exceed 2.2kpa, and the monthly average value shall not exceed 1.8ka;
c. Altitude: when the product is applicable to 12kV, the altitude shall not exceed 1000m; When the product is applicable to 7.2kV, the altitude shall not exceed 3000m
d. The surrounding air is not obviously polluted by dust, smoke, corrosive or combustible gas, vapor or salt mist;
e. Vibration or ground motion from outside the switchgear and control equipment is negligible;
f. The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kv;


Special use conditions

The user and the manufacturer shall negotiate when using under normal environmental conditions exceeding GB / t11022 and this instruction manual.

Technical Parameters

 Switch Cabinet Technical Parameters Table 1
No Item Unit Parameters
1 Rated Voltage
kV
 
12
2 Rated Insulation Level 1 min Power Frequency Withstand Voltage 42
Lightning Impulse Withstand Voltage 75
3 Rated Frequency Hz 50
4 Rated Current of Main Busbar A 630,     1250
5 Rated Short-Circuit Breaking Current 
kA
 
20,   25,    31.5
6 Rated Short-Time Withstand Current 20,   25,    31.5
7 Rated Withstand Current (Peak Value) 50,   63,    80
8 Rated Short-Circuit Breaking Current 50,   63,    80
9 Protection Level   IP3X
10 Outline Dimension (width x depth x length) mm 900 x 950 x 2300

Isolation Switch Technical Parameters Table 2
No. Item Unit Parameters
GN19 - 12C/630 GN19-12C/1250
GN30 - 12/630 GN30 - 12/1250
GN30 - 12D/630 GN30 - 12D/1250
1 Rated Voltage kV 10
2 Rated Current A 630 1000
3 4s Rated Short-Time Withstand Current kA 20 31.5
4 Rated Withstand Current (Peak Value) kA 50 80
5 Rated Insulation Level 1 min Power Frequency Withstand Voltage kV
 
42
Lightning Impulse Withstand Voltage 75
 
Vacuum Circuit Breaker Technical Parameters Table 3
No Item Unit Parameters
1 Rated Voltage
kV
 
12
2 Rated Insulation Level Power Frequency Withstand Voltage 75
Lightning Impulse Withstand Voltage 42
3 Rated Frequency Hz 50
4 Rated Current of Main Busbar A 630,     1250
5 Rated Short-Circuit Breaking Current 
kA
 
20,   25,    31.5
6 Rated Short-Time Withstand Current 20,   25,    31.5
7 Rated Withstand Current (Peak Value) 50,   63,    80
8 Rated Short-Circuit Breaking Current 50,   63,    80
9 Rated Back-to-Back Capacitor Bank Breaking Current A 400
10 Rated Operating Order   O-0.3s-CO-180s-CO
11 Mechanical Life Times 20000
12 Rated Short-Circuit Breaking Current Breaking Times Times 50
11 Main Circuit Resistance μΩ ≤ 40
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15