Lzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current Transformers

Application: Instrument, Metering
Type: Voltage Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LZZBJ18 -35W
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Altitude
Should Not Exceed 4000m
Air Relative Site
Outdoor
Rated Secondary Current
5A or 1A
Rated Frequency
50Hz or 60Hz
Insulation Level
40.5/95/200kv
Power Factor
Cosφ=0.8(Lag)
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Photos of Product
Lzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current TransformersLzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current TransformersLzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current Transformers
General


This type of current transformer adopts epoxy-resin vacuum casting and a fully closed single-phase structure, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 35kV, used for electric energy metering and current measurement and relay protection, it can be an arbitrary combination of classes 0.2S, 0.2, 0.5 and 10P.

It complies with the standards GB 20840.1 - 2010 Instrument transformers 
Part 1: General requirements, GB 20840.2 - 2014 Instrument transformers
Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers


Model And Meaning

Lzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current Transformers
Normal Usage Conditions
  1. Altitude: should not exceed 4000m
  2. Ambient temperature: -40ºC ~ +40ºC
  3. Air relative site: Outdoor.
Technical Parameters
  1. Compliance Standards: GB/T 20840.1&3 and IEC61869-1&2
  2. Insulation level:40.5/95/200kV
  3. Power factor:cosφ=0.8(lag)
  4. Rated secondary current: 5A or 1A
  5. Rated frequency:50Hz or 60Hz
  6. Weight: 80kg
Technical Ratio

Table 1: Single Parameter Ratio
 
Rated Primary
Current (A)
Accuracy class Rated output(VA) Rated Short-Time Thermal Current(kA/S) Rated Insulation Level (kA)
50


0.2S/0.5/10P10/10P10
0.2S/0.5/10P20/10P20



 
15/15/30/30
15/15/20/20
3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 72
600 43.2 81
800 57.6 120
1000-1800 0.2S/0.5/10P30/10P30 15/15/20 72 144

Table 2: Double Parameter Ratio
 
Rated Primary
Current (A)
Accuracy class Rated output(VA) Rated Short-Time Thermal Current(kA/S) Rated Insulation Level (kA)
50 - 100


0.2S/0.5/10P10
0.2S/0.5/10P20



 
15/15/30
15/15/20
7.2 18
60 - 120 8.64 21.6
75 - 150 10.8 27
80 - 160 11.52 28.8
100 - 200 14.4 36
150 - 300 21.6 54
200 - 400 28.8 72
250 - 400 36 90
300 - 600 43.2 108
400 - 800 57.6 120
500 - 1000 72 144
600 - 1200
800 - 1600

Table 3: Tripple Parameter Ratio
 
Rated Primary
Current (A)
Accuracy class Rated output(VA) Rated Short-Time Thermal Current(kA/S) Rated Insulation Level (kA)
50-75-100


0.2S/0.5/10P10/10P10
0.2S/0.5/10P20/10P20



 
15/15/30/30
15/15/20/20
7.2 18
75-100-150 10.8 27
100-150-200 14.4 36
150-200-300 21.6 54
200-300-400 28.8 72
300-400-500 36 90
200-400-600 43.2 108
400-600-800 57.6 120
500-600-800 57.6 120
600-800-1000 72 144

Outline And Installation Dimension

Lzzbj18 -35W Outdoor Single Phase Instrument Energy Meter Fully Enclosed Post Types of Current Transformers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15