• Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer

Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer

Application: Instrument, Metering
Type: Combined Transformer
Phase: Three
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
JLS3 -10(6)W
Insulating Medium
Steel Shell Type
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined TransformerJls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined TransformerGENERAL

It is a combination of current and voltage transformers, with an oil-immersed structure suitable for outdoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and current/voltage measurement, its connection mode is V/V.

It complies with the standards GB 20840.1 - 2010 Instrument transformers 
Part 1: General requirements, and GB 20840.2 - 2014 Instrument transformers
Part 2: Additional requirements for Current Transformers, and GB 20640.4-2013 Instrument Transformers
Part 3: Additional requirements for Inductive Voltage transformers, and GB 20640.4-2015 Instrument Transformers

Part 4: Additional requirements for combined Transformers


MODEL AND MEANING

Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
NORMAL USAGE CONDITIONS
  1. Altitude: should not exceed 2000m
  2. Ambient temperature: -40ºC ~ +40ºC
  3. Relative Humidity: ≤ 85%
  4. Installation site: Outdoor.
  5. Pollution Grade: III

TECHNICAL PARAMETERS
  1. Compliance Standards: GB/T 20840.1&3 and IEC61869-1&2
  2. Insulation level:12/42/75kV, 7.2/30/60kV
  3. Power factor:cosφ=0.8(lag)
  4. Rated frequency:50Hz or 60Hz
  5. Weight: 90kg
 
Table 1: Current Part of the Technical Parameters
 
Type Rated Primary Current (A) Accuracy Class - Rated Output Short-time thermal Current (kA/s) Rated Dynamic Stability Current (kA)
JLS3-6W 5 - 500 0.2S - 10 60l 1n 150l 1n
JLS3-10W 5 - 500 0.2S - 10 60l 1n 150l 1n
 
Table 2: Voltage Part of the Technical Parameters
 
Type Rated Voltage Ratio (V) Accuracy Class - Rated Output (VA) Limit Output (VA)
JLS3-6W 6000/100 0.2 - 15 300
JLS3-10W 10000/100 0.2 - 15 300
 

OUTLINE AND INSTALLATION DIMENSION

Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer
WIRING SCHEMATIC DIAGRAM

Jls3 -10 (6) W Outdoor / Three-Phase Oil-Immersed Type Combined Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now