Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer

Product Details
Customization: Available
Application: Instrument, Metering
Type: Combined Transformer
Still deciding? Get samples of US$ 300/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment methods: visa mastercard discover JCB diners club american express T/T
  Support payment in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
  • Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
Find Similar Products

Basic Info.

Model NO.
JLS3 -10(6)W
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Steel Shell Type
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Altitude
Should Not Exceed 2000m
Relative Humidity
≤ 85%
Installation Site
Outdoor.
Rated Frequency
50Hz or 60Hz
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
100.00cm * 80.00cm * 70.00cm
Package Gross Weight
120.000kg
Lead Time
30 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
GENERAL


It is a combination of current and voltage transformers, with an oil-immersed structure suitable for outdoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and current/voltage measurement, its connection mode is V/V.

It complies with the standards GB 20840.1 - 2010 Instrument transformers 
Part 1: General requirements, and GB 20840.2 - 2014 Instrument transformers
Part 2: Additional requirements for Current Transformers, and GB 20640.4-2013 Instrument Transformers
Part 3: Additional requirements for Inductive Voltage transformers, and GB 20640.4-2015 Instrument Transformers
Part 4: Additional requirements for combined Transformers



MODEL AND MEANING

Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
NORMAL USAGE CONDITIONS
  1. Altitude: should not exceed 2000m
  2. Ambient temperature: -40ºC ~ +40ºC
  3. Relative Humidity: ≤ 85%
  4. Installation site: Outdoor.
  5. Pollution Grade: III

TECHNICAL PARAMETERS
  1. Compliance Standards: GB/T 20840.1&3 and IEC61869-1&2
  2. Insulation level:12/42/75kV, 7.2/30/60kV
  3. Power factor:cosφ=0.8(lag)
  4. Rated frequency:50Hz or 60Hz
  5. Weight: 90kg
 
Table 1: Current Part of the Technical Parameters
 
Type Rated Primary Current (A) Accuracy Class - Rated Output Short-time thermal Current (kA/s) Rated Dynamic Stability Current (kA)
JLS3-6W 5 - 500 0.2S - 10 60l 1n 150l 1n
JLS3-10W 5 - 500 0.2S - 10 60l 1n 150l 1n
 
Table 2: Voltage Part of the Technical Parameters
 
Type Rated Voltage Ratio (V) Accuracy Class - Rated Output (VA) Limit Output (VA)
JLS3-6W 6000/100 0.2 - 15 300
JLS3-10W 10000/100 0.2 - 15 300
 

OUTLINE AND INSTALLATION DIMENSION

Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer
WIRING SCHEMATIC DIAGRAM

Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined TransformerTest Reports
All products have undergone professional testing and certification.
Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined TransformerJls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined TransformerOur Customer

Our customers are located all over the world.
Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined TransformerPhotos of Product
Jls3 -10 (6) W Outdoor / Three-Phase Voltage/Current Oil-Immersed Instrument Type Potential Combined Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier