• Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers
  • Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers
  • Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers
  • Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers
  • Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers

Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type and Energy-Storage Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vacuum Circuit Breaker
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LW38
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Break Load Current, Over-Load Current
Certification
ISO9001-2000
Rated Frequency
50Hz
Rated Voltage
40.5kv
Rated Current
1250 / 1600 / 2000A
Mechanical Life
6000times
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

General
 
LW38-40.5w outdoor AC High-Voltage Sulfur Hexafluoride(SF6) circuit breaker (hereinafter referred to as "circuit breaker") is an outdoor high-voltage distribution switchgear with three-phase AC 50Hz and rated voltage of 40.5kV. It can be used to open and close rated current and fault current, switch on and off capacitor banks, and switch lines. It is especially suitable for frequent operation and can also be used as a contact circuit breaker. 

The circuit breaker uses SF6 gas as the arc extinguishing and insulation quality is installed outdoors and adopts the elevated porcelain column structure.

The circuit breaker complies with technical standards such as GB / t1984-2014 high voltage AC circuit breaker, DL / t402-2016 high voltage AC circuit breaker, and JB / T 9694-2008 high voltage AC sulfur fluoride circuit breaker.

Model Description
Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit BreakersUsage Environmrntal Condition
  1. Altitude: 1000m, If the altitude is higher than 1000m, the rated insulation level shall be corrected accordingly.
  2. Ambient temperature: -40 oC ~ +45 oC, 
  3. Maximum daily temperature difference: 25 K 
  4. Humidity: Average daily relative humidity: 95%, average monthly relative humidity: 90%. 
  5. Sunshine intensity: not more than 0.1W/cm 2 
  6. Wind Speed: 34m/s 
  7. Wind pressure: 700Pa
  8. Pollution level: e - level
  9. Icing thickness: Not more than 10mm 
  10. Resistance to floor drain: horizontal acceleration 0.3g, vertical acceleration 0.2g
Main Advantages

☆ SF6 gas arc extinguishing and insulation, excellent insulation performance;
☆ Simple structure, long maintenance cycle;
☆ Strong breaking capacity and long mechanical life;
☆ Either built-in or external current transformer, with high measurement accuracy;
☆ Built-in intelligent wet temperature controller to ensure the safe and reliable operation of the circuit breaker in cold regions;
☆ The overall sealing design of the shell is improved to effectively prevent the adverse effects of sandstorms and other bad weather on the circuit breaker.

MainTechnical Parameters
 
No. Item Unit Data
1 Rated frequency Hz 50
2 Rated voltage kV 40.5
3 Rated current A 1250 / 1600 / 2000
4 Rated Short-Circuit Breaking Current kA 31.5
5 Rated Short-Circuit Closing Current 80
6 Rated Short-Time Withstand Current 31.5
7 Rated Peak Withstand Current 80
8 Rated Out of Step Breaking Current 10
9 Rated Short-Circuit Continuous Time  s 4
10 Rated Short-Circuit Breaking Current Breaking Times Times 10
11
Rated short-time power frequency withstand voltage
Interphase, to earth(dry) kV/min 95/1
Fracture (dry) 118/1
Interphase, to earth(wet) 80/1
Auxiliary circuit to earth 2/1
12 Rated lightning impulse withstand voltage Interphase, to earth kV 185
Fracture 215
13 Rated Operating Voltage and Auxiliary Circuit Rated Voltage V AC220, DC220
14 Main Circuit Rsistance Rated Current 1600A and below μΩ ≤ 90
Rated Current more than 1600A ≤ 40
15 Closing Time Under AC Voltage ms
 
≤ 100
Under DC Voltage 55 ~ 100
16 Opening Time Under AC Voltage ≤ 60
Under DC Voltage 30 ~ 65
17 Closing - Opening Time ≤ 120
18 Opening - Closing Time ≤ 50
19 Full Breaking Time ≤ 78
20 Rated Operating Order O - 0.3s - CO -180s- CO
21 Moving Contact Travel mm 96±2.5
22 Contact Opening Distance mm 60±1.5
23 Closing buffer Stroke mm 10±2
24 Phase-to-Phase opening Synchronism ms ≤ 3
25 Phase-to-Phase closing Synchronism ms ≤ 3
26 Phase spacing mm 725 
27 Annual Gas Leakage rate of SF6 % ≤ 0.5
28
 
SF6 Gas Moisture content (ppm, gauge pressure at 20 degrees Celcius) Handover Acceptance Value V/V ≤ 150
Distance Travel ≤ 300
29 SF6 Gas Rated Pressure (gauge pressure at 20oC) MPa 0.45
30 SF6 Gas Replenish Pressure (gauge pressure at 20 oC) 0.42
31 SF6 Gas Locked Pressure (gauge pressure at 20oC) 0.4
32 Mechanical Life Times 6000
33 SF6 Gas Weight Kg 5
34 Weight (with CT) 800
Weight (without CT) 1000
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.

Outline And Installation Dimension

Lw38-40.5W Outdoor AC High-Voltage Sulfur Hexafluoride Sf6 Air Electrical Electric Circuit Breakers
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15