High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer

Product Details
Customization: Available
Application: Power
Phase: Three
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
  • High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer
Find Similar Products

Basic Info.

Model NO.
TRANS
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
EI
Transport Package
Export Wooden Case
Trademark
DGG
Origin
China
HS Code
8504210000
Production Capacity
5000PCS/Year

Product Description

High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry TransformerHigh Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer

General

This production can be used in a wide range of area,especially in the place of high fire protection requirement. ie,mine,oilfield,subway station,power plant , school, shopping center, skyscraper and all indoor configuration system.


 

STRUCTURE CHARACTERISTICS:

  • Iron core : core applies excellent cold rolling oriental silicon sheet and 45°wholly sloped joint no punching hole structure ; surface of the core is coated with special resin to protect against rusting , elastic materials are cushioned between the clamping parts and core, between the clamping parts and core, between coils and between the core and the base seat to reduce operation noise.
  • Coils: low voltage winding applies double cylinder type or fossil type, high voltage winding applies sectional connection type structure; which is wounded by F class insulated polyester double fibre glass copper conductor and reinforced by fibre glass, epoxy resin proportion is poured and moulded under vacuum state. It has good electric performance and mechanical strength.
  • Temperature control: apply automatic temperature control protection system; realize temperature display, patrol inspection, start and stop air fan, over temperature alarm,tip and communication interface of computer etc functions on demand of users.
 


References:

ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles - Specifications and test methods.
IEC 60076: Power transformers.
IEC 60044: Instrument transformers.
IEC 60296: Specification for unused mineral insulating oil for transformers and switchgear.
IEC 60354: Loading guide for oil - immersed power transformers.
IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide.
IEC 60512: Connectors for electronic equipment.

High Voltage 10kv 200kVA 250kVA 800kVA Step Down Dry Transformer


Technical specification:
 
Rated capacity (kVA) voltage combination Vector group Losses(120°kW) No-load current(%)
HV(kV) tapping range LV(kV) On-load loss No-load loss
30         0.71 0.19 3.2
50         1 0.27 2.8
80         1.38 0.37 2.6
100         1.57 0.4 2.4
125         1.85 0.47 2.2
160         2.13 0.54 2.2
200 6       2.53 0.62 2
250 6.3       2.76 0.72 2.2
315 6.6 ±5%   Yyno 3.47 0.88 1.8
400 10   0.4   3.99 0.98 1.8
500 10.5 ±2x2.5%   Dyn11 4.88 1.16 1.8
630 11       5.88 1.34 1.6
630         5.96 1.3 1.6
800         6.96 1.52 1.6
1000         8.13 1.77 1.4
1250         9.69 2.09 1.4
1600         11.73 2.45 1.4
2000         14.45 3.05 1.2
2500         17.17 3.6 1.2




 
Rated capacity (kVA) voltage combination Vector group Losses(120°kW) No-load current(%)
HV(kV) tapping range LV(kV) On-load loss No-load loss
50         1.23 0.3 2.3
100         1.98 0.47 1.9
160         2.46 0.58 1.7
200         2.93 0.64 1.6
250         3.4 0.73 1.5
315   ±5%   Yyno 4.06 0.84 1.4
400 20,22   0.4   4.82 1 1.3
500 24,10 ±2x2.5%   Dyn11 5.76 1.17 1.3
630 11,12       6.8 1.32 1.2
800         8.22 1.52 1.1
1000         9.73 1.79 1
1250         11.48 2.06 1
1600         13.79 2.41 0.9
2000         16.29 2.8 0.9
2500         19.27 3.34 0.8