Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Still deciding? Get samples of US$ 1300/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
  • Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
Find Similar Products

Basic Info.

Model NO.
DGNPD
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection
Rated Voltage (Effective Value) Kv
60-207kv
Withstand Voltage(Kv)
85-200kv
Withstand Voltage (Peak Value) (Kv)
180-550kv
Special Long-Distance Voltage
48-166kv
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
80.00cm * 50.00cm * 45.00cm
Package Gross Weight
120.000kg
Lead Time
30 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
General


110kV and above power systems adopt the operation mode of neutral point direct grounding, commonly known as a high current effective grounding system. The neutral point of the transformer in operation is directly grounded, so there is no overvoltage and protection problem with the neutral point. However, in actual operation, in order to limit single-phase short circuit current, prevent communication interference, relay device setting configuration, and other requirements, the operation mode of ungrounded neutral points of some transformers is often adopted. Generally, only 30%~50% of the transformer neutral points are allowed to be directly grounded, so as to ensure the safe and stable operation of the system. In addition, in some ring or radial power supply networks, the dispatcher controls the power flow direction according to the operation needs and consciously arranges the neutral point of a certain intermediate terminal transformer to operate in a non-direct grounding mode. Obviously, under the condition of three-phase symmetry in the normal operation of the system, the neutral point potential is zero regardless of whether it is grounded or not, and there is no need to take overvoltage protection measures. However, in operation, it is often interfered with by various factors (such as lightning, operation, refusal to move, disconnection, single-phase grounding fault, etc.), and the neutral point of the transformer will have high overvoltage and be damaged, so it must be protected.

The electric power industry standard DLT620-1997 Overvoltage Protection and Insulation Coordination for AC Electrical Installations stipulates that "local ungrounded systems should be avoided in 110KV and 220KV effectively grounded systems, and excessive power frequency over-voltage should be generated. For such partially ungrounded systems, the over-voltage protection of 110kV and 220kV ungrounded neutral points with power supply on the low-voltage side should adopt the method of zinc oxide lightning arrester plus parallel clearance"


DGNPD series transformer neutral point gap grounding protection complete device (hereinafter referred to as the complete device) produced by our company is a complete device developed to protect against the damage of transformer neutral point insulation transformer overvoltage, switching overvoltage and power frequency [transient] overvoltage.


Model And Meaning

Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
Usage  Environmental Conditions


1. Outdoor Use
2. Ambient Temperature: Not lower than -40ºC, not higher than +40ºC
3. Relative Humidity: Not higher than 90% (25ºC)
4. Altitude: Not over 3000m
5. Power grid frequency: 48 ~ 52Hz (50Hz systems), 58 ~ 62Hz (60Hz systems)
6. Installation site: the air shall be free of chemical corrosive gas and steam, and explosive dust.



Technical Specification
 
Product Code Transformer's Neutral point withstand
level
Zinc oxide arrester Discharge barrier Isolation Switch 
1.2/50μs Lightning Impulse Withstand Voltage (peak value) (kV) 1 min Short-time Power frequency withstand Voltage(kV) Rated Voltage (effective value)
kV
Special long-distance voltage (effective value) kV DC 1mA reference voltage is not less than 8/20μs 1.5kA lightning impulse current residual voltage is not less than kV Power frequency discharge voltage (effective value) ± 5% kV Rated Voltage Peak Value Withstand Current (kA) 10s Short-Time Withstand Current (kA)
DGNPD-85/180-60 180 85 60 48 86 144 67.5 400 15.5 4.2
DGNPD-95/250-72 250 95 72 58 103 186 81 400 15.5 4.2
DGNPD-140/325-96 325 140 96 77 137 260 108 400 15.5 4.2
DGNPD-140/325-102 325 140 102 82 158 260 115 400 15.5 4.2
DGNPD-200/400-144 400 200 144 116 205 320 162 400 15.5 4.2
DGNPD-230/500-207 550 200 207 166 292 440 234 630 50 20

Test Reports
All products have undergone professional testing and certification.
Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit BreakerDgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit BreakerOur Customer

Our customers are located all over the world.
Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker
Photos of Product
Dgnpd Sf6 Electric High Voltage Transformer Load Break Switch Neutral Point Grounding Protection Device Vacuum Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier