Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type and Energy-Storage Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: Vacuum Circuit Breaker
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LW8
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Break Load Current, Over-Load Current
Certification
ISO9001-2000
Wind Speed
34m/S
Wind Pressure
700PA
Pollution Level
E - Level
Icing Thickness
Not More Than 10mm
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

PHOTOS OF PRODUCT

GENERAL
 
LW8-40.5 outdoor high-voltage sulfur hexafluoride circuit breaker (hereinafter referred to as "circuit breaker") is outdoor electrical equipment with three-phase AC 50Hz, which is applicable to the control and protection of 35kV Power Transmission and distribution system and can also be used to connect circuit breakers and switch capacitor banks.

LW8 - 40.5 circuit breaker is equipped with CT T14 spring operating mechanism.

The circuit breaker meets the requirements of GB / T 1984-89 AC high voltage circuit breaker and IEC publication high voltage AC circuit breaker.

MODEL DESCRIPTION

LW 38 - 40.5 (W) / T    --    -  -- 
L      = Sulfur Hexafluoride(SF6) circuit breaker
W     = Outdoor
8      = Design Serial Number
40.5 = Rated Voltage (kV)
W    = Anti-fouling
T     = Spring Operating Mechanism
--     = Rated Current (A)
--     = Rated Short-circuit Breaking Current (kA)


USAGE: ENVIRONMENTAL CONDITION
  1. Altitude: 1000m, If the altitude is higher than 1000m, the rated insulation level shall be corrected accordingly.
  2. Ambient temperature: -40 oC ~ +45 oC, 
  3. Maximum daily temperature difference: 25 K 
  4. Humidity: Average daily relative humidity: 95%, average monthly relative humidity: 90%. 
  5. Sunshine intensity: not more than 0.1W/cm 2 
  6. Wind Speed: 34m/s 
  7. Wind pressure: 700Pa
  8. Pollution level: e - level
  9. Icing thickness: Not more than 10mm 
  10. Resistance to floor drain: horizontal acceleration 0.3g, vertical acceleration 0.2g
MAIN TECHNICAL PARAMETERS
 
No. Item Unit Data
1 Rated Voltage kV 40.5
2 Rated Insulation Level Lightning Impulse Withstand Voltage (Full-wave Peak Value) 185/215 (Fracture)
Power Frequency Withstand Voltage (1 minute) 95
3 Rated Current A 1600, 2000
4 Mechanical Life Times 3000
5 SF6 Gas Rated Pressure (gauge pressure at 20oC) Mpa 0.45
6 Locked Pressure (gauge pressure at 20oC) Mpa 0.45
7 Minimum Operating Ambient Temperature oC -30
8 Rated Short-Circuit Breaking Current kA 25,  31.5
9 Rated Short-Circuit Closing Current (Peak Value) 63,     80
10 Rated Short-Circuit time Withstand Current (Thermal Stable Current) 25,  31.5
11 Rated Peak Value Withstand Current (Strive to Stabilize the Current) 63,     80
12 Rated Out of Step Breaking Current 63,     80
13 Rated Short-circuit Continuous Time S 4
14 Closing - Opening Time  Not more than 0.1
15 Opening - Closing Time  Not more than 0.1
16 Rated Operating Order   Open- 0.3s - Close Open - 180s - Close Open
17 Rated Opening and Closing Current of Single Capacitor Bank A 400
18 Under Rated Short-Circuit Breaking Current's Cumulative Breaking Times   Times 15,   10
19 Annual Leakage Gas % year Not more than 1
20 SF6 Gas Moisture content (20oC) PPm (V) Not more than 50
21 Rated Operating Voltage of CT14 Spring Operating Mechanism V 220V
Closing Coil, Opening Coil Voltage AC220, DC110, 220
Voltage of Energy Storage Motor AC220,  DC220
22 SF6 Gas Weight Kg 8
23 Circuit Breaker (Including Operating Mechanism) Weight  1400
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.

OUTLINE AND INSTALLATION DIMENSION

Lw8-40.5 Outdoor Sf6 High-Voltage Central Cabinet Medium Voltage Pole Mounted Vacuum Circuit Breaker Switch

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15