Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer

Product Details
Customization: Available
Application: Metering
Type: Current Transformer
Still deciding? Get samples of US$ 20/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
  • Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
Find Similar Products

Basic Info.

Model NO.
LXK
Phase
Single
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Rated Secondary Current
5A or 1A
Power Factor
Cosφ=0.8(Lag)
Rated Frequency
50Hz or 60Hz
Altitude
Should Not Exceed 1000m
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Packaging & Delivery

Package Size
50.00cm * 30.00cm * 25.00cm
Package Gross Weight
10.000kg
Lead Time
15 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
GENERAL


These series of transformers are used indoors. They are used for three phases of overdriven current protection in the electric not-useful-ground neutral system up to rated frequency 50Hz or 60Hz and rated voltage 35kV. The transformers are fitting with the relay too.

Being installed, at first, make the product dimidiation. Then make it coalition use bolt. Can be loaded in hot-line conditions.



MODEL AND MEANING
Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
NORMAL ENVIRONMENTAL CONDITIONS
  1. Altitude: Should not exceed 1000m
  2. Ambient temperature: -5ºC ~ +40ºC
  3. Air relative humidity: ≤85%
  4. Air relative site: Indoor.

TECHNICAL PARAMETERS
    1. Rated secondary current: 5A or 1A
    2. Power factor: cosφ=0.8(lag)
    3. Rated frequency: 50Hz or 60Hz
    4. Rated primary current, rated output, and accurate level see table 1
    5. Insulating property: primary winding to secondary winding and ground, and secondary winding to the ground can bear the power frequency withstand voltage 3kV for 1min.
    Table 1: Current Part of the Technical Parameters
     
    Rated primary current(A) Accuracy Class Rated Output (VA)
    60-75 10P5 2.5
    100 3.75
    150 2.5
    200-300 3.75
    400-600 5
    100 2.5
    150-200 10P10 2.5
    300-400 3.75
    500 5
    600 5
     
     
    Type of Relay Connecting Method of Relay Windings Relay Calibration Primary Zero Sequence Current
    LJK-Φ120
    LJK-Φ160
    Series 15x1 2-5
    30x1
    Parallel 15x2 3-8
    30x2
    LJK-Φ200 Series 15x1 3-6
    30x1
    Parallel 15x2 3-10
    30x2

     
    OUTLINE AND INSTALLATION DIMENSIONS
    Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
    Model Number ΦD Φd H h a b c e
    LXK(KXLXK) - Φ80 165 80 175 82.5 120 104 120 56
    LXK(KXLXK) - Φ100 180 100 195 92.5
    LXK(KXLXK) - Φ120 204 120 215 102.5
    LXK(KXLXK) - Φ150 234 150 245 117.5
    LXK(KXLXK) - Φ180 263 180 275 132.5
    LXK(KXLXK) - Φ200 303 200 320 156
    LXK(KXLXK) - Φ240 347 240 385 185 160 120 142 80
     
    Our Customer

    Our customers are located all over the world.
    Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
    Test Reports

    All products have undergone professional testing and certification.
    Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer
    Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current TransformerPhotos of Product
    Lxk Dia (80~240) Indoor / Zero Single Phase Epoxy-Resin Type Zero Sequence Current Transformer

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now
    Contact Supplier