• Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
  • Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
  • Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
  • Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
  • Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
  • Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv

Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv

Application: Instrument, Metering
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LZZBJ9
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Insulation Level
12/42/75kv
Rated Secondary Current
5A or 1A
Power Factor
CosΦ=0.8(Lag)
Altitude
Should Not Exceed 1000m
Air Relative Site
Indoor
Rated Frequency
50Hz or 60Hz
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Photos of Product
Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kvFully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv
General

This type of current transformer adopts epoxy-resin vacuum casting and fully enclosed post structure, is applicable for power systems of rated frequency 50Hz or 60Hz rated voltage up to and including 10kV, used for electric energy metering, current measurement, and relay protection, it can be an arbitrary combination of classes 0.2S, 0.2, 0.5 and 10P.

It complies with the standards GB20840.1-2010 Instrument transformers-Part 1: General requirements, GB 20840.2-2014 Instrument transformers- Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers.

 
 
Technical parameter
  1. Insulation level:12/42/75kV
  2. Power factor:cosΦ=0.8(lag)
  3. Rated secondary current: 5A or 1A
  4. Rated frequency:50Hz or 60Hz
  5. Weight: 27kg
Transformer ratio
 
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal
current(kA/s)
Rated insulation level(kA)
5 0.2S
0.2S/0.5
0.2S/0.5/10P10
0.2S/10P10
10
10/10
10/10/15
10/15
0.36 0.9
10 0.72 1.8
15 1.08 2.7
20 1.44 3.6
25 1.8 4.5
30 2.16 5.4
40 2.88 6.3
50 3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 72
600 43.2 108
800 57.6 120
1000-1500 72 144

Use environment
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative site: indoor
Fully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kvFully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kvFully Enclosed Indoor Types of Single Phase Energy Meter Current Instrument Transformers with 12kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15