Secured Trading Service

11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear

Denggao Electric Co., Ltd.
  • Audited Supplier
  • 8 yrs
  • leading factory

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Epoxy-Resin Vacuum Casting: Adopts fully enclosed post structure for superior insulation and durability.
  • Wide Accuracy Class Options: Arbitrary combination of classes 0.2S, 0.2, 0.5, and 10P available.
  • Flexible Customization: Supports full, minor, sample-based, and design-based customization options.
  • Dual Frequency Support: Rated frequency options include 50Hz and 60Hz for global compatibility.
  • ISO Management Certified: Certified under ISO9001:2015, ISO14001, and ISO45001:2018 standards.
  • OEM and ODM Services: Professional manufacturer offering both OEM and ODM service capabilities.
  • 100% Finished Product Inspection: All units undergo visual and functional inspection before delivery.
  • Fast Lead Time: Average lead time within 15 workdays for both peak and off-peak seasons.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear

11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear pictures & photos
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
  • 11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
    11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear

Find Similar Products

Product Description

Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
General

This type of current transformer adopts epoxy-resin vacuum casting and fully enclosed post structure, is applicable for power systems of rated frequency 50Hz or 60Hz rated voltage up to and including 10kV, used for electric energy metering, current measurement and relay protection, it can be arbitrary combination of classes 0.2S, 0.2, 0.5 and 10P.
It complies with the standards GB20840.1-2010 Instrument transformers-Part 1: General requirements, GB 20840.2-2014 Instrument transformers- Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers.

Use environment
  1. Altitude:should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative site:indoor.

Technical parameter
  1. Insulation level:12/42/75kV
  2. Power factor:cosΦ=0.8(lag)
  3. Rated secondary current: 5A or 1A
  4. Rated frequency :50Hz or 60Hz
  5. Weight: 21kg
Transformer ratio
 
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal
current(kA/s)
Rated insulation level(kA)
5 0.2S
0.2S/0.5
0.2S/0.5/10P10
0.2S/10P10
10
10/10
10/10/15
10/15
0.36 0.9
10 0.72 1.8
15 1.08 2.7
20 1.44 3.6
25 1.8 4.5
30 2.16 5.4
40 2.88 6.3
50 3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 72
600 43.2 108
800 57.6 120
1000-1500 72 144

Test Reports
All products have undergone professional testing and certification.
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for SwitchgearPhotos of Product
11kv Indoor Zero Phase Split Core Instrument Voltage/Potential Small Size CT or Current Transformer for Switchgear
 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR2531526". Items marked "verified" are certified.

Watch Video
Watch Video
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.
Denggao Electric Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 208 Weiwu Rd, Yueqing Economic Development Zone, Yueqing, Wenzhou, Zhejiang, China
verified Plant Area
36095.13 square meters
verified Number of Employees
427
verified Registered Capital
118,000,000 RMB
verified Terms of Payment
LC, T/T
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Ningbo Port, Shanghai Port
verified Minimum Order Quantity
1 Set
verified Supply Chain Partners
32

Our Production Capability & Technical Expertise

verified Main Products
Voltage Transformer‬, ‪Drop-out Fuse Cutout‬, ‪Lightning Arrester‬, ‪Vacuum Circuit Breaker‬, ‪Switchgear
verified Production Lines
5
verified Production Machines
Laser Cutting Facility, Bending Facility, Punching Facility, Die Casting Facility, Winding Line
verified QA/QC inspectors
40 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
30 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
1996-09-15
verified Export Year
29 Years
verified Main Markets
Southeast Asia/ Mideast, Domestic
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
15
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
No

FAQ

What is the rated voltage range for this transformer?
It is applicable for power systems with rated voltage up to and including 10kV.
Can the accuracy class be customized?
Yes, it allows for arbitrary combinations of classes 0.2S, 0.2, 0.5, and 10P.
Is OEM or ODM service available?
Yes, the manufacturer offers both OEM and ODM services with flexible customization.
What is the minimum order quantity?
The minimum order quantity is 1 set.
What payment terms are accepted?
Accepted payment terms include LC and T/T.
Does the product meet international standards?
Yes, it complies with GB20840.1-2010, GB 20840.2-2014, and JJG 313-2010 standards.
What is the maximum operating altitude?
The altitude should not exceed 1000m.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now