Pid Intelligent Digital Abt Temperature Controller Meter

Product Details
Customization: Available
After-sales Service: Upon Request
Warranty: Upon Request
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Pid Intelligent Digital Abt Temperature Controller Meter
  • Pid Intelligent Digital Abt Temperature Controller Meter
  • Pid Intelligent Digital Abt Temperature Controller Meter
  • Pid Intelligent Digital Abt Temperature Controller Meter
  • Pid Intelligent Digital Abt Temperature Controller Meter
Find Similar Products

Basic Info.

Model NO.
ABT
Installation
General Installation Meter
Display
Digital
Usage
Standard Electric Energy Meter
Theory
Electric Apparatus
Power Source
AC
DC Voltmeter Type
Electrostatic
AC Voltmeter Type
Electric
Customized
Customized
Accuracy of Measurement
Class 0.2
Sampling Period
0.25s
Control Period
1 ~ 120s
Relay Contact Switch Output
250VAC/2A, 30VDC/2A
Transport Package
PCB
Specification
96*48
Trademark
DGG or no brand or OEM
Origin
Zhejiang
HS Code
9030331000

Product Description

Chapter 1. General introduction

The ABT series intelligent temperature controller can be applied in the control and alarm in a range of -200 ~ 2300ºC. It can use in the controller and alarm of pressure, discharge, liquid level, humidity, etc, parameters when fitted with the corresponding transmitter.

The key features include

1. 18 kinds of input signals including signals of thermocouple, resistance thermometer detector (RTD), direct voltage, and direct current can be input freely.
2. Freely changeable with on-off control or PID control with configurable direct reverse action modes. It has the self-tuning function of PID parameter.
3. Control output supports relay contact switch, solid-state relay (SSR) driving voltage, single-phase thyristor zero-crossing trigger signal, direct voltage, and direct current.
4. One way of programmable alarm outputs is provided with a number of alarm modes including higher limit, and lower limit. In addition, the alarm features can also be temporarily disabled when applying power.
5. Comprehensive self-detection and protection-- In case of error, it provides automatic repair or prompt message and closes the output.



Chapter 2.Model and definition

Pid Intelligent Digital Abt Temperature Controller Meter
Chapter 3.General parameters
 
v TInput Type Code Measuring range Input Type Code Measuring range
Thermocouple (TC) K -100ºC ~ +1350ºC Resistance thermometer detector (RTD)
 
Cu50 -50ºC ~ +150ºC
S -50ºC ~ +1750ºC Pt100 -200ºC ~ +850ºC
R -50ºC ~ +1750ºC
DC Voltage (U)
 
0 - 5V Customized range within 
-1999 ~ +9999
T -200ºC ~ +400ºC 1 - 5V
E -100ºC ~ +1000ºC 0 - 10V
J -100ºC ~ +1200ºC DC Current
(I)
0 - 20mA
B 600ºC ~ +1800ºC 4 - 20mA
N -100ºC ~ +1300ºC      
L -100ºC ~ +800ºC
WRe3-WRe25 0ºC ~ +2350ºC
WRe5-WRe26 0ºC ~ +2350ºC
 
3.2 Accuracy of measurement: class 0.2 (± 0.2% FS ± 0.1ºC). Thermocouple Cold-end Compensation deviation: ± 2ºC
3.3 Sampling period: 0.25s
3.4 Control period: 1 ~ 120s (free set)
3.5 Control modes (free changeable)
ON/OFF control(configurable direct/reverse action and differential gap)
PID control (configurable direct/reverse action, manual or automatic configuration of PID parameters)
3.6 Output specifications
Relay contact switch output: 250VAC/2A, 30VDC/2A
Solid-state relay (SSR) driving voltage output: 5 ~ 12VDC/25mA
Single-phase thyristor zero-crossing trigger signal: 85 ~ 264V/50 ~ 60Hz, capable of triggering 5 ~ 500A TRIAC or 2 SCRs in inverse parallel connection or thyristor power module.
DC current output: 0 - 5V, 1 - 5V switchable output linearity ≤ 0.5%, output load resistance ≥ 1kΩ, electrically isolated from signal inputs and auxiliary power supply.
3.7 Alarm mode (free switchable)
Five kinds of alarm modes: Higher absolute values, lower absolute values, higher limit deviation values, lower limit deviation values, and higher and lower limit deviation values. Besides, it can set the releasing alarm characteristics when the instrument is powered on to avoid alarm misoperation when powered on.
3.8 Working power supply: 220V ± 10% / 50 ~ 60Hz, power consumption < 3W
3.9 Operational environment: places free of corruption with a temperature of 0 ~ 50ºC, and relative humidity ≤ 85% RH



Chapter 4. Shape and Hole cutout dimension
 
Panel Dimension Code Panel dimension Case dimension Hole cutout dimension
W H W H D W H
A 96 96 91 91 80 92 92
D 72 72 67 67 80 68 68
E 48 96 44 90 80 45 92
F 96 48 90 44 80 92 45
G 48 48 44 44 80 45 45