• High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer
  • High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer
  • High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer
  • High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer
  • High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer
  • High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer

High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer

Application: Metering
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LMZ
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

GENERAL

This type of transformer adopts an integral casting structure, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 0.66kV, used for current measurement, electric energy metering, relay protection, etc.

It complies with the standard Q/GDW1572-2014 Technical specification of a low-voltage current transformer for metering.



NORMAL ENVIRONMENTAL CONDITIONS
  1. Altitude: Should not exceed 1000m
  2. Ambient temperature: -5ºC ~ +40ºC
  3. Air relative humidity: ≤85%
  4. Air relative site: Indoor.

TECHNICAL PARAMETERS
    1. Rated secondary current: 5A or 1A
    2. Power factor: cosφ=0.8(lag)
    3. Rated frequency: 50Hz or 60Hz
    4. Rated primary current, rated output, and accurate level see table 1
    5. Insulating property: primary winding to secondary winding and ground, and secondary winding to the ground can bear the power frequency withstand voltage 3kV for 1min.
    Table 1: Current Part of the Technical Parameters
     
    Type Rated primary current(A) Rated output VA(COSΦ =0.8lag)
    0.2S 0.2 0.5S 0.5 1
    LFZ1D-DGG1 10-60 5-2.5 5-2.5 5-2.5 5-2.5 5-2.5
    LMZ(1D,2D)-DGG1 75-500 5-2.5 5-2.5 5-2.5 5-2.5 5-2.5
    LMZ(3D,4D)-DGG1 600-1500 10-3.75 10-3.75 10-3.75 10-3.75 10-3.75



    OUTLINE AND INSTALLATION DIMENSIONS

    High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer 
    Type 2: 
    Model Rated Primary Current (A) H H1 M L1 Remarks
    LMZ(1D, 2D, 3D, 4D) -DGG1 75-200 138 7 74 34  
    300-500 138 9 54 46  
    600-800 146 30 54 84  
    1000-1500 164 50 54 104  


    OUTLINE AND INSTALLATION DIMENSIONS

    High Voltage 800/5A 400/5A 250/5A 100/5A 5/1A Lmzj1-0.5s 0.2s Current Transformer


     

    Send your message to this supplier

    *From:
    *To:
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now

    You Might Also Like

    360° Virtual Tour

    Diamond Member Since 2019

    Suppliers with verified business licenses

    Manufacturer/Factory & Trading Company
    Number of Employees
    302
    Year of Establishment
    1996-09-15