Factory Price Dgnpd - Type Transformer Neutral Point Grounding Protection Device

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Overcurrent Protection
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DGNPD
Ambient Temperature
-40ºC-+40ºC
Altitude
Not Over 3000m
Power Grid Frequency
48 ~ 52Hz
Relative Humidity
Not Higher Than 90% (25ºC)
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

PHOTOS OF PRODUCT

GENERAL 

110kV and above power systems adopt the operation mode of neutral point direct grounding, commonly known as a high current effective grounding system. The neutral point of the transformer in operation is directly grounded, so there is no overvoltage and protection problem with the neutral point. However, in actual operation, in order to limit single-phase short circuit current, prevent communication interference, relay device setting configuration, and other requirements, the operation mode of ungrounded neutral points of some transformers is often adopted. Generally, only 30%~50% of the transformer neutral points are allowed to be directly grounded, so as to ensure the safe and stable operation of the system. In addition, in some ring or radial power supply networks, the dispatcher controls the power flow direction according to the operation needs and consciously arranges the neutral point of a certain intermediate terminal transformer to operate in a non-direct grounding mode. Obviously, under the condition of three-phase symmetry in the normal operation of the system, the neutral point potential is zero regardless of whether it is grounded or not, and there is no need to take overvoltage protection measures. However, in operation, it is often interfered with by various factors (such as lightning, operation, refusal to move, disconnection, single-phase grounding fault, etc.), and the neutral point of the transformer will have high overvoltage and be damaged, so it must be protected.

The electric power industry standard DLT620-1997 Overvoltage Protection and Insulation Coordination for AC Electrical Installations stipulates that "local ungrounded systems should be avoided in 110KV and 220KV effectively grounded systems, and excessive power frequency over-voltage should be generated. For such partially ungrounded systems, the over-voltage protection of 110kV and 220kV ungrounded neutral points with power supply on the low-voltage side should adopt the method of zinc oxide lightning arrester plus parallel clearance"

DGNPD series transformer neutral point gap grounding protection complete device (hereinafter referred to as the complete device) produced by our company is a complete device developed to protect against the damage of transformer neutral point insulation transformer overvoltage, switching overvoltage and power frequency [transient] overvoltage.


MODEL AND MEANING
Factory Price Dgnpd - Type Transformer Neutral Point Grounding Protection DeviceUSAGE ENVIRONMENTAL CONDITIONS

1. Outdoor Use
2. Ambient Temperature: Not lower than -40ºC, not higher than +40ºC
3. Relative Humidity: Not higher than 90% (25ºC)
4. Altitude: Not over 3000m
5. Power grid frequency: 48 ~ 52Hz (50Hz systems), 58 ~ 62Hz (60Hz systems)
6. Installation site: the air shall be free of chemical corrosive gas and steam, and explosive dust.


TECHNICAL SPECIFICATION
 
Product Code Transformer's Neutral point withstand
level
Zinc oxide arrester Discharge barrier Isolation Switch 
1.2/50μs Lightning Impulse Withstand Voltage (peak value) (kV) 1 min Short-time Power frequency withstand Voltage(kV) Rated Voltage (effective value)
kV
Special long-distance voltage (effective value) kV DC 1mA reference voltage is not less than 8/20μs 1.5kA lightning impulse current residual voltage is not less than kV Power frequency discharge voltage (effective value) ± 5% kV Rated Voltage Peak Value Withstand Current (kA) 10s Short-Time Withstand Current (kA)
DGNPD-85/180-60 180 85 60 48 86 144 67.5 400 15.5 4.2
DGNPD-95/250-72 250 95 72 58 103 186 81 400 15.5 4.2
DGNPD-140/325-96 325 140 96 77 137 260 108 400 15.5 4.2
DGNPD-140/325-102 325 140 102 82 158 260 115 400 15.5 4.2
DGNPD-200/400-144 400 200 144 116 205 320 162 400 15.5 4.2
DGNPD-230/500-207 550 200 207 166 292 440 234 630 50 20

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15