• Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
  • Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
  • Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
  • Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
  • Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
  • Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter

Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Overcurrent Protection
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZW32-12Y
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

General

ZW32-12Y Series outdoor AC vacuum circuit breaker is 12kV distribution equipment of 3 phase,50Hz. According to user requirements, a prepaid circuit breaker's high-voltage metering box can be a three-phase three-wire system(V/V connection) or a three-phase four-wire system(Y/Y connection), and the metering current transformer can be a single ratio or multi ratio. The ratio range is (2.5~1200)/5.

Meaning And Model

Outdoor Sf6 High Voltage Isolating Vacuum Load Circuit Breakers Switch Interrupter
VCB's Main Technical Data
 
 
No. Item Unit Data
1 Rated frequency Hz 50
2 Rated voltage kV 12
3 Rated current A 630/1250
4 Rated short-time power frequency withstand voltage Interphase, to earth(wet) kV/min 42/1
    Interphase, to earth(dry)   48/1
    Break(dry)   34/1
    Secondary circuit to earth   2/1
5 Rated lightning impulse withstand voltage Interphase, to earth kV 75
    Break   85
6 Rated short-circuit breaking current kA 20/25
7 Rated short-circuit making current(peak)   50/63
8 Rated short-time withstand current and duration kA/s (20/25)/4
9 Rated peak withstand current kA 50/63
10 Rated short-circuit breaking current breaking times Times 30
11 Rated operating voltage and rated voltage of the auxiliary circuit V AC/DC220,DC48,DC24
12 Main circuit resistance Without isolation μΩ ≤80
    With isolation   ≤120
13 Mechanical life Times 10000
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.
 
High-voltage metering main technical data
No. Item Unit Data
1 Rated frequency Hz 50
2 (cosΦ)Power factor   0.8(lag)
3 Rated primary voltage 3-phase 3-wire system kV 10
3-phase 4-wire system 10/√3
4 Rated secondary voltage 3-phase 3-wire system 0.1/0.22
3-phase 4-wire system (0.1/√3)/0.22
5 PT wiring method 3-phase 3-wire system   V-V
3-phase 4-wire system   Y-Y
6 Rated primary current A 5~600
7 Rated secondary current 5
8 PT accuracy class   0.2/3
9 CT accuracy class   0.2S
10 PT rated output VA 15/200
11 PT ultimate output 500(class3)
12 CT rated output 10
13 Polarity   Subtractive polarity
14 Rated short-time power frequency withstand voltage kV/min 42/1
15 Rated lightning impulse withstand voltage kV 75

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15