Type: High-voltage
Structure: Three-column Disconnector
Installation: Outdoor High-voltage
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Horizontal Rotary Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
GW4A
Number of Poles
Three Pole
Structure of Operating
Electric
Certification
ISO
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
853530900
Production Capacity
10000PCS/Year

Product Description

Photos of Product
Gw4a-12 Series Outdoor High-Voltage AC Isolator Switch Disconnectors Disconnector/DisconnectingGw4a-12 Series Outdoor High-Voltage AC Isolator Switch Disconnectors Disconnector/DisconnectingGw4a-12 Series Outdoor High-Voltage AC Isolator Switch Disconnectors Disconnector/DisconnectingGw4a-12 Series Outdoor High-Voltage AC Isolator Switch Disconnectors Disconnector/Disconnecting
General

GW4A-12 series finished hairpin improved outdoor high-voltage AC isolation switch(hereinafter referred to as "Isolation switch") is an outdoor high-voltage switchgear with a rated frequency of 50Hz, which is used for switching 10kV High-voltage Line under voltage and no load, and for the electrical isolation of overhauled high-voltage bus, circuit breaker and other electrical equipment from live high-voltage lines, It can also be used to close very small capacitive current and inductive current.

The Isolation switch meets the technical standards of high voltage AC disconnectors and earthing switches (GB/T 1985-2014) and high voltage AC disconnectors and earthing switches (DL/T 486-2010).



Model And Meaning
Gw4a-12 Series Outdoor High-Voltage AC Isolator Switch Disconnectors Disconnector/Disconnecting

Usage: Environmental Condditions
  1. Altitude: no more than 1000m. If the altitude is higher than 1000m, the rated insulation level shall be corrected accordingly.
  2. Ambient temperature: upper limit + 45 0C, lower limit - 40 0C, average temperature of the hottest month 30 0C, maximum daily temperature difference 25K.
  3. Solar radiation intensity (outdoor): 0.1W/cm2
  4. Wind speed / pressure (outdoor): 34m/s  /  700Pa
  5. Pollution level: e-level
  6. Icing thickness: not more than 20mm
  7. Humidity: average daily relative humidity, not more than 95%, average monthly relative humidity not more than 80%
  8. Earthquake resistance: horizontal acceleration 0.3m/2, vertical acceleration 0.15m/s2
  9. Safety factor: sinusoidal resonance three cycle wave, safety factor above 1.67.


Main  Advantages
  1. It adopts a perfect and improved design, no welding is required for installation, and the operation is simple and convenient.
  2. It adopts double column middle opening and contact transfer in structure, which has the ability of automatic contact cleaning and strong operation reliability.
  3. The contact finger uses high strength, high conductivity, and high elasticity materials, which can clamp the contact by relying on its own elasticity, avoiding the vicious cycle caused by the reduction of contact clamping force caused by spring corrosion and heating annealing, the increase of contact resistance and the intensification of contact heating.
  4. The insulator is made of high-strength porcelain material and designed with a large creepage distance. It has strong pollution resistance and environmental adaptability and can meet the operation requirements in high-altitude areas.
  5. The rotating part shall be designed according to maintenance-free requirements.

Technical Parameters
 
No. Item Unit Data
1 Rated Frequency Hz 50
2 Rated Voltage kV 12
3 Rated Current A 630 1250 2000 2500
4
5
Rated Short-time Withstand Current 
Rated Short-Time Withstand Current(Peak Value)
kA 20/4 25/31.5 31.5 31.5/40
50/63 63/80 80 80/100
6 Rated short-time power frequency withstand voltage kV/min 42/1 (Interphase, to earth)
48/1 (Fracture)
7 Rated lightning impulse withstand voltage kV 75 (Interphase, to earth)
85 (Fracture)
8 Rated Short-Time Withstand Current Continuous Time s 4 (Isolation Switch) 2 (Earthing Switch)
9 Circuit resistance μΩ ≤100 ≤80
10 Mechanical life Times 2000 (Isolation Switch/Earthing Switch)
11 Creepage distance mm ≥372 (e - Level)
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.
 