Fzw28-12f Sf6 Electric Electrical Air Automatic Recloser Vacuum Circuit Breakers Interrupter

Breaking Capacity: High Voltage Circuit Breakers
Operation: Manual Type
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Type: Circuit Breaker
Function: Conventional Circuit Breaker, Overcurrent Protection
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FZW28-12F
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Photos of Product

General
 
1.1  New problem of the distribution network as below:

1. When the main trunk circuit is modified, the branch line failure rate is rising;
2. Due to the failure of branch line user and protect mismatch, spread to the whole feeder power outages and lead to liability disputes;
3. Transformer substation grounding selected-line equipment can not satisfy quick find grounding point demand;
4. Due to protective circuits with multilevel add delay, worsening of power network working.
FZW28-12F type excellent solves the problem as above.



1.2  Function of boundary switch (watchdog).


Automatic removal of single-phase grounding fault
When a single-phase grounding fault occurs in the branch line of the user, the tap changer will automatically open, and the users of the substation and other branches on the feeder line will not feel the occurrence of the fault.

Automatic isolation of phase-to-phase short circuit fault
In case of a phase-to-phase short-circuit fault of the user's branch line, the boundary switch shall be opened immediately after the outgoing line protection of the substation trips. After the substation is reclosed, the fault line is automatically isolated, and other branch users on the feeder line quickly recover the power supply (equivalent to a transient fault).

Quickly locate the fault point
After the boundary switch protection action is caused by the fault of the user's branch line, only the responsible user is responsible for the power failure. The fault information shall be actively submitted by the user, and the power company can quickly send personnel to the site for troubleshooting; If the boundary switch is equipped with a communication module, it will automatically send the information to the power management center.

Monitor user load
The boundary switch can be configured with wired or wireless communication accessories to transmit the monitoring data to the power management center to realize remote real-time data monitoring of the user's load.

1.3  The boundary switch complies with GB / T 3804-2004 (3.6kV ~ 40.5kV high voltage AC load switch) and DL (Remote terminal of distribution automation system)

Model Description
Fzw28-12f Sf6 Electric Electrical Air Automatic Recloser Vacuum Circuit Breakers Interrupter 
Main Technical Paramters
 
No. Item Unit Data
1 Rated frequency Hz 50
2 Rated voltage kV 12
3 Rated current A 630
4
Rated short-time power frequency withstand voltage
Interphase, to earth(wet) kV/min 34/1
Interphase, to earth(dry) 42/1
Fracture (dry) 49/1
Secondary circuit to earth 2/1
5 Rated lightning impulse withstand voltage Interphase, to earth kV 75
Fracture 85
6 Rated short-time withstand current and duration kA/s 20/4
7 Rated peak withstand current kA 50
8 Rated short-circuit making current(peak) 50
9 Annual Air leakage rate MPa  500
10 Main circuit resistance μΩ ≤550
12 Mechanical life Times 10000 
Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate.

Outline And Installation Dimension

Fzw28-12f Sf6 Electric Electrical Air Automatic Recloser Vacuum Circuit Breakers Interrupter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15