Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Aluminum Alloy
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
  • Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv
Find Similar Products

Basic Info.

Model NO.
KYN61
Voltage Level
Medium Voltage
Installation
Fixed
Structure
Withdrawable
Standard
IEC62271-200, IEC62271-100
Trademark
DGG
Origin
China
HS Code
853720900
Production Capacity
100sets/Year

Product Description

Photos of Product
Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kvKyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kvKyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kvKyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv

General

KYN61-40.5 (z) AC metal-enclosed switchgear (hereinafter referred to as switchgear) is used in the 35kV three-phase AC 50Hz power system, as the power distribution room of power plants, substations, and industrial and mining enterprises to receive and distribute electric energy, and has the functions of control, protection, and monitoring.

This product meets the requirements of GB3906 3-35kv AC metal-enclosed switchgear, GB / T11022 common technical requirements for high voltage switchgear and control equipment standards, IEC 60298 AC metal-enclosed switchgear and control equipment with rated voltage above 1kV and below 52kv and iec60694 common terms for high voltage switchgear and control equipment.


Model And  Meaning

Kyn61-40.5 Indoor Metal-Clad Electrical Air Insulated Substation Switchgears with Withdrawable Vcb Vacuum Circuit Breaker 30kv 33kv 35kv


Normal Service Conditions

1. The ambient air temperature shall not exceed 40 ºC, and the average value measured within 24h shall not exceed 35 ºC. The minimum ambient air temperature shall be - 25 ºC
2. The altitude shall not exceed 1000m, and the altitude under special use conditions shall not exceed 2000m;
3. The surrounding air is not obviously polluted by dust, smoke, corrosive and/or combustible gas, vapor, or salt mist
4. The average relative humidity measured within 24h shall not exceed 95%, the average water vapor pressure measured within 24h shall not exceed 2.2kpa, the average monthly relative temperature shall not exceed 90%, and the average monthly water vapor pressure shall not exceed 1.8kpa
5. When the equipment is installed, the inclination with the vertical plane shall not exceed 5 °;
6. The equipment shall be installed in a place free from violent vibration and impact.
Note: if users have special requirements, they can negotiate with our company.

 

Technical Parameters
 
No. Item Unit Data
1 Rated Voltage kV 40.5
2 Rated Current Main Bus Bar A 1600/2500
Matching Circuit Breaker A 166/2500
3 Rated Insulation Level 1min frequency withstand voltage (Interphase, inter phase, between fractures) kV 95/110
Lightning Impulse Withstand voltage (Peak), Interphase, inter phase / between Fractures kV 185/215
Frequency Withstand Voltage Auxiliary Circuit, Control Circuit  V/1min 2000
4 Rated Frequency Hz 50
5 Rated Short Circuit Breaking Current kA 31.5
6 Rated Short-time Withstand Current/Rated Short Circuit Duration kA/s 31.5/4s
7 Rated Withstand Current (peak) kA 80
8 Rated Short Circuit Making Current  kA 80
9 Rated Voltage of Control circuit  V DC:110 220,AC:110 220
10 Protection class Switchgear Enclosure   IP4X
Compartment (when the cabinet door is opened)   IP2X
 