Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard

Product Details
Customization: Available
Certification: CCC, ISO9001
Shell Material: Aluminum Alloy
Still deciding? Get samples of US$ 5000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
  • Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
Find Similar Products

Basic Info.

Model NO.
GGD
Installation
Removable
Structure
Cabinet
Rated Voltage
380V
Rated Withstand Voltage (Ka)
30/63/105ka
Rated Current
440/660/1000A
Rated Short-Circuit Breaking Current
15/30/50ka
Transport Package
Wrapped
Trademark
DGG
Origin
China
HS Code
853720900
Production Capacity
100sets/Year

Product Description

Photos of Product
Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/SwitchboardGgd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/SwitchboardGgd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/SwitchboardGgd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
General


GGD Low voltage fixed switchgear (hereinafter referred to as "distribution cabinet") is suitable for power users such as power plants, substations, industrial and mining enterprises, etc as power, lighting and power conversion, distribution, and control of distribution equipment in the distribution system with AC 50h (60Hz), rated working voltage 380V (400V), (660V) and rated current up to 3150A. The product has the characteristics of high breaking capacity, good dynamic and thermal stability, rated short-time withstand current up to 50kA, flexible electrical scheme, convenient combination, strong practicability, novel structure, and high protection grade. This product is one of the representative products of assembled and fixed panel switchgear in China.

The power distribution cabinet has undergone a comprehensive type test and passed the national compulsory product 3C certification.  The product complies with GB7251.1 "Low-voltage switchgear and control equipment", IEC60439-1 "Low-voltage switchgear and control equipment" and other standards.


Model And Meaning

Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
Usage: Environmental Conditions

1. The ambient air temperature shall not exceed 40 ºC. And the average value measured within 24h shall not exceed 35 ˚ C. Minimum ambient air temperature - 5˚C.
2. The altitude of the installation site shall not exceed 2000 meters.
3. The surrounding air is not appreciably polluted by dust, smoke, corrosive and/or flammable gases, vapors, or salt mist.
4. Atmospheric conditions: the air is clean. When the maximum temperature is + 40 ºC, the relative humidity shall not exceed 50%. The higher relative humidity is allowed at lower temperatures. For example, the relative humidity is 90% at + 20 ºC. However, it should be considered that due to the change in temperature, moderate condensation may occur occasionally.

5. When the equipment is installed, the inclination from the vertical plane should not exceed 5˚C.
6. The equipment should be installed in a place free from severe pulling and impact.
7. Note: Users can negotiate with our company for special requirements.



Technical Parameters

Model no. Rated Voltage Rated Current Rated Short-Circuit Breaking Current (kA) Rated Short-Time Withstand Current (1s)(kA) Rated Withstand Voltage (kA)
GGD1 380 (400) (660) A 1000
15
 

15
 

30
 
B 660 (630)
C 400
GGD2
380 (400) (660)
 
A 1600(630)
30
 

30
 

63
 
B 1000
C 1250
D 660 (630)
GGD3

380 (400) (660)

 
A 3150

50

 


50

 


105

 
B 2500
C 2000
D 1600(1500)
E 1250
F 1000


Outline Diemension
 
Ggd Fixed Transformer Substation Power Distribution Cabinet Box Switchgear/Switchboard
Product Outline Code A B C D Remarks
06 600 600 450 550  
06A 600 800 450 750  
08 800 600 650 550  
08A 800 800 650 750  
10 1000 600 850 550  
10A 1000 800 850 750  
12 1200 800 1050 750  