• Current Transformer for Vacuum Breaker
  • Current Transformer for Vacuum Breaker
  • Current Transformer for Vacuum Breaker
  • Current Transformer for Vacuum Breaker
  • Current Transformer for Vacuum Breaker
  • Current Transformer for Vacuum Breaker

Current Transformer for Vacuum Breaker

Application: Metering
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LZW32-10
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Current Transformer for Vacuum BreakerGENERAL

This type of current transformer adopts a full silicone rubber sheathed structure, is applicable for vacuum circuit breaker switching systems and power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for relay protection, its class level is 10P

It complies with the standards GB 20840.1 - 2010 Instrument transformers 
Part 1: General requirements, GB 20840.2 - 2014 Instrument transformers
Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers



MODEL AND MEANING

Current Transformer for Vacuum BreakerCurrent Transformer for Vacuum Breaker

NORMAL USAGE CONDITIONS
  1. Altitude: should not exceed 4000m
  2. Ambient temperature: -25ºC ~ +40ºC
  3. Air relative site: Indoor.

TECHNICAL PARAMETERS
  1. Compliance Standards: GB/T 20840.1&3 and IEC61869-1&2
  2. Insulation level:12/42/75kV
  3. Power factor:cosφ=0.8(lag)
  4. Rated secondary current: 5A or 1A
  5. Rated frequency:50Hz or 60Hz
  6. Weight: 15kg

TECHNICAL PARAMETERS

Table 1: Transformation Ratio Parameters
 
Rated Primary
Current (A)
Rated Secondary Current (A) Class Combination Rated Output (VA) Insulation Level
100-200-300 5
 


10P10


 
1.25/2.5/3.75 12/42/75
200-300-400 2.5/3/3.75 12/42/75
200-400-600 5/7.5/10 12/42/75
20 (Zero Sequence) 1 3 0.1 12/42/75


OUTLINE AND INSTALLATION DIMENSION
Current Transformer for Vacuum BreakerCurrent Transformer for Vacuum Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15