Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM

Product Details
Customization: Available
Application: Metering
Type: Current Transformer
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
  • Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
Find Similar Products

Basic Info.

Model NO.
LZZBJ9
Phase
Single
Operation Condition
Outdoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Insulation Level
40.5/95/200kv
Power Factor
Cosφ=0.8(Lag)
Rated Secondary Current
5A or 1A
Rated Frequency
50Hz or 60Hz
Altitude
Should Not Exceed 4000m
Air Relative Site
Outdoors
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Photos of product
Indoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEMIndoor Single Phase Energy CT Meter Post Types of Current Instrument Transformers for OEM
General


This type of voltage transformer adopts epoxy-resin vacuum casting and a fully closed single-phase structure for indoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and voltage measurement.
It complies with the standards GB 20840.1-2010 Instrument transformers-Part1:General requirements, GB 20840.3-2013 Instrument transformers-Part3:Additional requirements for inductive voltage transformers, and JJG314-2010 Instrument Voltage Transformers.


Technical parameter

1.Insulation level:40.5/95/200kV
2.Power factor:cosφ=0.8(lag)
3.Rated secondary current: 5A or 1A
4.Rated frequency :50Hz or 60Hz
5.Weight: 95kg


Technical ratio
 
Single parameter ratio        
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal current(kA/s) Rated insulation level(kA)
50 0.2S/0.5/10P10/10P10
0.2S/0.5/10P20/10P20
15/15/30/30
15/15/20/20
3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 72
600 43.2 81
800 0.2S/0.5/10P30/10P30 15/15/20/20 57.6 120
1000-1600 72 144
 
Dual-ratio parameter        
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal current(kA/s) Rated insulation level(kA)
50-100 0.2S/0.5/10P10/10P10
0.2S/0.5/10P20/10P20
15/15/30/30
15/15/20/20
7.2 18
60-120 8.64 21.6
75-150 10.8 27
80-160 11.52 28.8
100-200-300 14.4 36
150-300 21.6 54
200-400-600 28.8 72
250-500 36 90
300-600 43.2 108
400-800 57.6 120
500-1000 72 120
600-1200 72 144
800-1600 100 160
 
Three parameters        
Rated primary current(A) Accuracy class Rated output(VA) Rated short-time thermal current(kA/s) Rated insulation level(kA)
50-75-100 0.2S/0.5/10P10/10P10
0.2S/0.5/10P20/10P20
15/15/30/30
15/15/20/20
7.2 18
75-100-150 10.8 27
100-150-200 14.4 36
150-200-300 21.6 54
200-300-400 28.8 72
300-400-500 36 90
200-400-600 43.2 108
400-600-800 57.6 120
500-600-800 57.6 144
600-800-1000 72 160

Use environment

1. Altitude: should not exceed 4000m
2.Ambient temperature:-5ºC~+40ºC
3. Air relative humidity:≤85%
4. Air relative site: outdoors.