• PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
  • PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
  • PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
  • PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
  • PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
  • PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type

PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type

Application: Metering
Type: Voltage Transformer
Phase: Three
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
JSZK-10
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 TypePT Voltage Transformer Indoor Dry Type 6kv Jszk-10 TypeGeneral

This type of voltage transformer adopts epoxy-resin vacuum casting, assembled by 4 single phase winding is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and voltage measurement.The product can effectively eliminate the frequency division, power frequency, and high-frequency resonance, will not be burned, and has a strong anti-ferromagnetic resonance and short circuit resistance.
It complies with the standards GB 20840.1-2010 Instrument transformers-Part 1: General requirements, GB 20840.3-2013 Instrument transformers-Part3:Additional requirements for inductive voltage transformers, and JJG 314-2010 Instrument Voltage Transformers.


Use environment
  1. Altitude: should not exceed 1000m
  2. Ambient temperature:-5ºC~+40ºC
  3. Air relative humidity:≤85%
  4. Air relative site: indoor.

Technical parameter
  1. Insulation level:12/42/75kV, 7.2/30/60kV
  2. Power factor:cosφ=0.8
  3. Rated frequency:50Hz or 60Hz
  4. Weight: 102kg
PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type
Technical ratio
 
Rated voltage ratio(kV) Accuracy class Rated output(VA) Limit output(VA)
6/0.1/0.1 0.2/0.2 15/15 300
6/0.1/0.22 0.2/3 15/100 300
10/0.1/0.1 0.2/0.2 15/15 300
10/0.1/0.22 0.2/3 15/100 300
PT Voltage Transformer Indoor Dry Type 6kv Jszk-10 TypePT Voltage Transformer Indoor Dry Type 6kv Jszk-10 Type

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
302
Year of Establishment
1996-09-15