| Number | Project | Unit | Parameters | |
| 1 | Rated Frequency | Hz | 50 | |
| 2 | Rated Voltage | kV | 12 | |
| 3 | Rated Current | A | 630/1250 | |
| 4 | Rated Short-Time Power Frequency Withstand Voltage | Phase, to earth (Wet type) | kV/min |
42/1 |
| Phase, to earth (Dry type) | 48/1 | |||
| Fracture (Dry type) | 34/1 | |||
| Secondary circuit to earth | 2/1 | |||
| 5 | Rated Lightning Impulse Withstand voltage | Phase, to earth | kV | 75 |
| Fracture | 85 | |||
| 6 | Rated short-circuit breaking current | kA | 20/25 | |
| 7 | Rated short-circuit making current (peak) | kA | 50/63 | |
| 8 | Rated short-time withstand current and duration | kA/s | (20/250/4 | |
| 9 | Rated peak value withstand current | kA | 50/63 | |
| 10 | Rated short-time breaking current breaking times | times | 30 | |
| 11 | Rated operating voltage and rated voltage of auxiliary(control) circuit | V | AC/DC220, DC48, DC24 | |
| 12 | Main Circuit Resistance | Without isolation switch | micro-ohms | ≤ 80 |
| With isolation switch | ≤ 120 | |||
| 13 | Mechanical Life | times | 10000 | |
| Note: If the altitude is higher than 1000m, the rated insulation level should be accordingly | ||||
| Number | Project | Unit | Parameters | |
| 1 | Rated Frequency | Hz | 50 | |
| 2 | Power Factor | cosΦ | 12 | |
| 3 | Rated Primary Current | A | 630/1250 | |
| 4 | Rated Secondary Voltage | Three-Phase, Three-wire | kV |
42/1 |
| Three-Phase, Four-wire | 48/1 | |||
| Three-Phase, Three-wire | 34/1 | |||
| Three-Phase, Four-wire | 2/1 | |||
| 5 | Voltage Transformer Connection mode | Three-Phase, Three-wire | kV | 75 |
| Three-Phase, Four-wire | 85 | |||
| 6 | Rated secondary current | A | 20/25 | |
| 7 | Accuracy class of voltage transformer | 50/63 | ||
| 8 | Accuracy class of current transformer | (20/250/4 | ||
| 9 | Rated output of Voltage transformer | VA | 50/63 | |
| 10 | Ultimate output of voltage transformer | VA | 30 | |
| 11 | Rated output of current transformer | VA | AC/DC220, DC48, DC24 | |
| 12 | Polarity | ≤ 80 | ||
| 13 | Rated short-time power frequency withstand voltage | kV/min | ||
| 14 | Rated lightning impulse withstand voltage | kV | ≤ 120 | |