Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer

Product Details
Customization: Available
Application: Instrument, Metering
Type: Voltage Transformer
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Patents Awarded
The supplier had awarded 4 patents, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
Product Certification
The supplier's products already have relevant certification qualifications, including:
KEMA
to see all verified strength labels (33)
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
  • Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
Find Similar Products

Basic Info.

Model NO.
LZZB11 -10
Phase
Single
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Epoxy Resin
Installation
Extension Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Export Box
Trademark
DGG
Origin
China
HS Code
8504311000
Production Capacity
100000PCS/Year

Product Description

Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current TransformerLzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current TransformerGENERAL

This type of current transformer adopts epoxy-resin vacuum casting and a fully closed single-phase structure for indoor use, is applicable for power systems of rated frequency 50Hz or 60Hz and rated voltage up to and including 10kV, used for electric energy metering and current measurement.

It complies with the standards GB 20840.1 - 2010 Instrument transformers 
Part 1: General requirements, GB 20840.2 - 2014 Instrument transformers
Part 2: Additional requirements for current transformers, and JJG 313-2010 Instrument Current Transformers


MODEL AND MEANING

Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
NORMAL USAGE CONDITIONS
  1. Altitude: should not exceed 1000m
  2. Ambient temperature: -5ºC ~ +40ºC
  3. Air relative site: Indoor.

TECHNICAL PARAMETERS
  1. Compliance Standards: GB/T 20840.1&3 and IEC61869-1&3
  2. Insulation level:12/42/75kV
  3. Power factor:cosφ=0.8(lag)
  4. Rated secondary current: 5A or 1A
  5. Rated frequency:50Hz or 60Hz
  6. Weight: 11kg
Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
TECHNICAL RATIO

Table 1: Transformation Ratio Parameters
 
Rated Primary
Current (A)
Accuracy class Rated output(VA) Rated Short-Time Thermal Current(kA/S) Rated Insulation Level (kA)
5 0.2S 10 0.36 0.9
10 0.72 1.8
15 1.08 2.7
20 1.44 3.6
25 1.8 4.5
30 2.16 5.4
40 2.88 6.3
50 3.6 7.2
60 4.32 8.1
75 5.4 13.5
80 5.76 14.4
100 7.2 18
120 8.64 21.6
150 10.8 27
200 14.4 36
250 18 45
300 21.6 54
400 28.8 63
500 36 90

Table 1: Transformation Ratio Parameters
 
Rated Primary
Current (A)
Accuracy class Rated output(VA) Rated Short-Time Thermal Current(kA/S) Rated Insulation Level (kA)
5-10 0.2S 10 0.72 1.8
10-20 1.44 3.6
15-30 2.16 5.4
20-40 2.88 7.2
25-50 3.6 9
30-60 4.32 10.8
40-80 5.76 14.5
50-100 7.2 18
60-120 8.64 21.6
75-150 10.8 27
80-160 11.52 28.8
100-200 14.4 36
150-300 21.6 54
200-400 28.8 63
250-500 36 90

Note: If the parameters requested by the user are beyond the scope of the above table, they can be determined after consultation with our company.


OUTLINE AND INSTALLATION DIMENSIONS
Lzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current TransformerLzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current TransformerLzzb11 -10 Indoor / Single-Phase Fully Enclosed Post Type Current Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier